Concrete Curb & Gutter Specifications: A Contractor's Reference

This reference summarizes the documents behind concrete curb and gutter in Southeast Texas. They include TxDOT Item 529, Class A concrete under Item 421, the CCCG-22 standard sheet, and Beaumont's street standards. Hollier Construction Services builds to the TxDOT and municipal specifications on each project's plans. On any job, the plans and the engineer of record govern over this summary.

How the Documents Fit Together

Curb on a public or commercial job rarely answers to one document. TxDOT's specifications set materials and workmanship. Standard sheets draw the shapes. The plans and the city code decide what gets built where.

TxDOT's Item 5 sets the order when they disagree. Special provisions govern over the plans, including general notes, and the plans govern over the specifications. Job-specific sheets beat standard sheets, and numerical dimensions beat scaled ones.

Item 5 also gives the Engineer the final word on which standard details apply, and it requires prompt reporting of errors or discrepancies. On city and private work, the plans and the engineer of record govern.

A practical reading order starts with the plan general notes and typical sections. Next come the standard sheets bound into the set, then the specification items they name. Raise any conflict before concrete is ordered.

Item 529 Materials and Class A Concrete

Item 529 of TxDOT's 2024 specifications covers concrete curb, gutter, and combined curb and gutter. It pulls materials from Items 360, 420, 421, and 440.

The default is Class A concrete unless the plans name another material. Extruded Class A uses Grade 8 coarse aggregate. Curb placed monolithically with concrete pavement takes the pavement's class instead.

Item 421 gives Class A a minimum design strength of 3,000 psi and a maximum water-to-cementitious ratio of 0.60. It lists curb and gutter among Class A uses and leaves curb slump as approved.

Fibers meeting DMS-4550 may replace reinforcing steel unless the plans say otherwise. Where bars are used, CCCG-22 calls for No. 4 bars unless shown differently.

Placement, Tolerance, and Curing

Item 529 requires a guideline set to the plan alignment. Grade and alignment changes may not exceed 1/4 inch between any two contacts on a 10-foot straightedge.

Formed curb goes in sections of 50 feet or less unless approved. It is struck off 1/4 to 3/8 inch undersize, plastered after initial set with one part cement to two parts fine aggregate, then brushed.

Slipformed or extruded curb needs approved self-propelled equipment, a mold that adjusts vertically on the move, and a gauge tracking the grade line. Hollier runs its own slip-form machine for barrier curb, roll curb, and valley gutter.

Curing follows Item 420, with a 72-hour minimum. Item 420 allows water or membrane curing on unformed surfaces. Compound goes on just after free moisture disappears, at about 180 square feet per gallon. Class A must be warmer than 50°F when placed.

Joints, Subgrade, and Base

Item 529 puts joints where the plans show them. Beside concrete pavement, curb joints match the pavement's joint type and location. Expansion joints run through the curb, and contraction joints are formed or sawed full depth in monolithic curb.

Away from concrete pavement, CCCG-22 places expansion joints at structures, at curb returns at streets, and where the Engineer directs. Half-inch expansion material goes where curb meets sidewalk or riprap.

The subgrade, foundation, or pavement surface is shaped and compacted to the plan line, grade, and cross-section, then lightly sprinkled just before the pour. Item 529 names no base material, so the plan typical section controls.

Utility trenches matter too. Beaumont's water utility specifications cover trenches under concrete streets and under asphalt streets with curb and gutter. Those are backfilled to the pavement bottom with clean sand and 1-1/2 sacks of cement per cubic yard, thoroughly tamped.

CCCG-22, Ramps, and Payment

TxDOT's roadway standards list now carries CCCG-22 for concrete curb and curb and gutter, a revision applicable December 2022. The earlier CCCG-21 applied from July 2021. CCCG-22 details Type I curb from 2 to 4 inches high and Type II from 5 to 5-3/4 inches. It also shows Type IIa curb and gutter and Type III keyed curb.

The sheet calls for exposed edges rounded to at least a 1/4-inch radius. Old curb is sawed or removed at existing joints. Ramps sit on TxDOT's separate PED-18 standard; slopes and landings are covered on our ADA curb ramps page.

Item 529 measures curb by the foot. It pays at the unit bid price for Concrete Curb, Concrete Curb (Mono), or Concrete Curb and Gutter of the type specified. That price includes preparing the curb foundation, and CCCG-22 pays a curb transition as the highest curb.

City of Beaumont Street Standards

Beaumont's Code Article 26.03 requires streets to follow the major street and highway plan and the city's official street construction standards and specifications.

Driveway and sidewalk work needs a permit approved by the Engineering Department and issued by Building Codes. Driveways get a pre-pour inspection once forms and steel are set, then a post-pour inspection. The city's water utility specifications send pavement replacement to the Engineering Division's standard details shown in the plans.

The article's street utility layout puts storm sewer one and one-half feet behind the curb. Sidewalks built at the back of curb must be at least five feet wide. Its other curb-related requirements include:

What concrete does TxDOT require for curb and gutter?

Item 529 and the CCCG-22 sheet call for Class A concrete unless the plans name something else. Item 421 sets Class A at a 3,000 psi minimum design strength with a 0.60 maximum water-to-cementitious ratio.

How long must new curb cure under Item 529?

At least 72 hours, using a method allowed by Item 420, such as water curing or a membrane compound. When the curb can take traffic is a separate call made by the plans or the engineer.

How far apart are expansion joints in concrete curb?

Item 529 leaves joint locations to the plans, though formed curb goes in sections no longer than 50 feet unless approved. Next to concrete pavement, curb joints match the pavement's. Elsewhere, CCCG-22 calls for expansion joints at structures, curb returns, and locations the Engineer directs.

What if the plans and the TxDOT specification disagree?

Under TxDOT Item 5, the plans and their general notes govern over standard specifications, and special provisions govern over both. Report the conflict to the engineer before building, since Item 5 treats late notice as a waiver of related claims.

Is CCCG-21 still the current curb standard sheet?

No. TxDOT's roadway standards list shows CCCG-22 as the revised sheet, applicable December 2022. Older plan sets may still bind in CCCG-21, and the sheet in the signed set is the one that applies.

Does Item 529 allow slip-form curb?

Yes. It covers extruded or slipformed curb placed with approved self-propelled equipment, using Grade 8 coarse aggregate for extruded Class A. Barrier curb, roll curb, and valley gutter all come off Hollier's slip-form machine.

Does every new street in Beaumont need curb and gutter?

No. Article 26.03 excuses rural streets in A-R zoning or the ETJ, temporary cul-de-sacs, and planning-area subdivisions built under Jefferson County rules. Residential and minor residential streets may use roll-type curb.

Where are ADA curb ramp details covered?

On state work, TxDOT draws ramps on its PED-18 standard, Pedestrian Facilities-Curb Ramps. Hollier's hand-form crews build ADA curb ramps, and our ADA curb ramps page covers slopes, landings, and detectable warnings.

TxDOT: 2024 Standard Specifications, Item 529, Concrete Curb, Gutter, and Combined Curb and Gutter

TxDOT: 2024 Standard Specifications, Item 421, Hydraulic Cement Concrete

TxDOT: 2024 Standard Specifications, Item 420, Concrete Substructures

TxDOT: 2024 Standard Specifications, Item 5, Control of the Work

TxDOT: Standard Sheet CCCG-22, Concrete Curb and Curb and Gutter

TxDOT: Roadway Standards (English)

City of Beaumont Code (eCode360): Article 26.03, General Design Principles and Specific Design Standards and Improvement Requirements

City of Beaumont: Water Utilities Department Standard Specifications

City of Beaumont: Frequently Asked Questions, Public Works (Engineering)